Flow Control

GF120X-110554

Brooks Instrument GF120-Series Metal-Sealed Thermal Mass Flow Controller

About this part

GF120X-110554 is a configured Brooks Instrument GF120-series high-purity digital thermal mass flow controller identifier. In Brooks ordering documentation, the GF120X prefix denotes a fixed-gas/range special-application build rather than a MultiFlo-capable configuration. An observed unit is associated with Applied Materials 0190-91650 and described for surface-mount N2 service, but its stated 2000 sccm range, EtherNet/IP interface, and model suffix conflict with current Brooks GF120XSD documentation. The complete Brooks model code, physical label, build record, or calibration certificate is required before using those attributes for replacement selection

Configurations vary. Verify the exact unit before choosing a replacement.

Key Facts

ManufacturerBrooks Instrument GF100 Series
Part numberGF120X-110554
Product familyGF120 Series
Device typeMass Flow Controller
Configuration statusConfiguration varies
Application classSemiconductor/high-purity gas delivery
CategoryFlow Control

Specifications

Identification
ManufacturerBrooks Instrument
Exact configured identifierGF120X-110554
Documented platformGF100 Series, GF120 model line
Measurement technologyDigital thermal mass-flow measurement and control for gases
Configuration
X configurability codeNot MultiFlo capable; a specific gas and range are required, and the Brooks standard-flow ordering table requires an SD, SL, or HA special-application option
Construction
Family flow-path contextCurrent GF100 Series documentation describes a metal-sealed, all-metal high-purity/ultra-high-purity flow path with SEMI F20 HP-compliant wetted materials. Exact installed materials and options remain configuration dependent
Controls
Documented family interfacesBrooks documents analog/RS-485, DeviceNet, and EtherCAT configurations for the GF100 Series. The connector portion of the complete model code is required to establish the installed interface; EtherNet/IP is not identified for GF120XSD in the current cited Brooks documents
Flow
GF120 SDS range contextCurrent Brooks documentation lists 4-25 sccm N2-equivalent for GF120XSL and greater than 25 sccm through 1 slpm N2-equivalent for GF120XSD. These limits apply only when the complete code confirms the corresponding SDS option
Performance
GF120 SDS settling-time contextCurrent Brooks documentation lists less than 3 seconds for GF120XSL and GF120XSD normally closed configurations; do not assert this value unless the complete model code confirms an SDS build

What Does GF120X-110554 Mean?

The public Brooks ordering structure supports decoding only the GF120X prefix. The numeric configured-part suffix is not defined in the published ordering tables.

SegmentFieldInterpretation
GFBase modelBrooks high-purity/ultra-high-purity digital mass flow controller.
120Package/model lineGF120 standard-flow platform. Special-application codes can change the applicable flow-range and response context.
XConfigurabilityNot MultiFlo capable; a specific gas and range are required. Brooks requires this value to be paired with an SD, SL, or HA special-application code.
110554Configured-part suffixNot decoded by the public Brooks ordering tables; it does not independently establish gas, range, fitting, valve, connector, calibration, or footprint.

Configuration Verification Boundaries

Documented SDS valve codeC, normally closed; required with Brooks SD, SL, and HA special-application codes.
Observed model transcriptionGF120XSD0/GF120XSDO is not a valid SDS prefix in the current Brooks ordering table because O is unavailable with SD or SL.
Observed flow claim2000 sccm N2 is outside the current documented GF120XSD range envelope.
Replacement selectionUse the complete physical-label model code, Brooks build record, or manufacturer-issued calibration documentation to establish compatibility.

Documentation Downloads

Local PDF copies

Part Photos

5 images

Historical archive images for identification, labels, connectors, and condition reference, not current inventory.

Historical Listings & Prices

Historical listing data, not a current offer
Archive records1Tracked historical listing records
Historical median price$1,204.25Based on archived listing records
Recorded price range$1,204.25 - $1,204.25Low to high recorded listing price
Local documents3PDF copies available from Sonisys
Recorded price context

The typical recorded price range is $1,204.25 to $1,204.25. Based on 1 archived listing record; not a current offer, appraisal, or confirmed sale price.

View archived listing titles
  • Brooks Instrument GF120X-110554 Mass Flow Controller MFC 2000 SCCM N2 New Spare

Archived listings

Other Part Numbers & Aliases

GF120X-110554Brooks GF120X-110554Brooks Instrument GF120X-110554