Flow Control

GF120X-109489

Brooks Instrument Metal-Sealed Thermal Mass Flow Controller

About this part

GF120X-109489 identifies a Brooks Instrument GF100-Series metal-sealed digital thermal mass flow controller for high-purity gas service. Brooks model-code tables establish that X denotes a non-MultiFlo configuration requiring a specific gas and range. This shortened identifier does not disclose the special application, gas, full-scale range, valve, fitting, or communications interface; those details require the complete product label or Brooks build record

Configurations vary. Verify the exact unit before choosing a replacement.

No archived photo available

Key Facts

ManufacturerBrooks Instrument GF100 Series
Part numberGF120X-109489
Product familyGF100 Series
Device typeMass Flow Controller
Configuration statusConfiguration varies
Application classSemiconductor/high-purity gas delivery
CategoryFlow Control

Specifications

Identification
ManufacturerBrooks Instrument
Product familyGF100 Series metal-sealed high-purity and ultra-high-purity thermal mass flow controllers and meters for gases
Exact configured identifierGF120X-109489
Observed device typeMass flow controller
Configuration
Configurability codeX — not MultiFlo capable; a specific gas code and full-scale range are required
Special applicationNot established by the shortened identifier. The GF100 model table requires X with an SD, SL, or HA special application, while the separate current high-temperature table uses HT nomenclature
Flow
Configured gas and rangeNot established; obtain the complete model code, product label, certificate of conformance, or Brooks build record
Performance
Published family accuracy contextThe current GF100 analog/DeviceNet data sheet lists ±1% of set point from 35-100% full scale and ±0.35% full scale from 2-35%, based on factory N2 calibration. Do not assert this as the unit's certified performance without its configuration record
Published family repeatability contextThe current GF100 family data sheet lists ±0.15% of set point from 5-100% and ±0.015% full scale from 2-5% for applicable configurations
Materials
Family wetted-path contextAll-metal high-purity flow path with SEMI F20 HP-compliant materials; exact wetted components and surface finish remain configuration dependent
Mechanical
Valve configurationNot established; GF-family options include normally closed, normally open on applicable models, and meter configurations without a valve
Process connection and footprintNot established by GF120X-109489
Controls
Installed communications interfaceNot established; connector or complete model-code evidence is required
Applications
Family application contextSemiconductor etch, implant, MOCVD, CVD, ALD, PVD, epitaxial, strip, and other high-purity gas-flow applications

What Does GF120X-109489 Mean?

The public Brooks ordering tables decode the GF120X prefix, but they do not define the hyphenated six-digit suffix as an ordering-code field.

SegmentFieldInterpretation
GFBase modelHigh-purity/ultra-high-purity digital mass flow controller platform
120Package/application platformThe standard GF100 analog/DeviceNet table associates 120 with a 3 sccm-55 slpm N2-equivalent envelope, 700 ms base response, and 5 µin Ra finish. The separate GF120xHT table instead defines a 50 sccm-5 slpm envelope, so these values are not configured-unit specifications until the special application is established.
XConfigurabilityNot MultiFlo capable; a specific gas code and range are required. The main table requires an SD, SL, or HA special application.
109489Configured-part suffixNo public Brooks ordering field maps this six-digit suffix. It must not be decoded into gas, range, valve, fitting, protocol, or application options without a Brooks build record.

Documented GF120X Special-Application Boundaries

These are documented configuration possibilities, not identified specifications for GF120X-109489.

CodeApplicationPublished boundary
SLSafe Delivery SystemGF120 only; 4-25 sccm N2-equivalent full-scale range
SDSafe Delivery SystemGF120 only; above 25 sccm through 1 slpm N2-equivalent full-scale range
HA / HTHigh-temperature configurationThe main GF100 table references HA but does not define it in the option list. The current dedicated GF120xHT table uses HT, lists 50 sccm-5 slpm N2-equivalent, and supports flow-module temperatures through 150°C. Do not equate or assign these codes to this unit without exact build evidence.

Replacement and Installation Verification

Matching the shortened identifier alone is insufficient for replacement compatibility.

Documentation Downloads

Local PDF copies

Part Photos

0 images

Historical archive images for identification, labels, connectors, and condition reference, not current inventory.

Historical Listings & Prices

Historical listing data, not a current offer
Archive records1Tracked historical listing records
Historical median price$1,211.24Based on archived listing records
Recorded price range$1,211.24 - $1,211.24Low to high recorded listing price
Local documents3PDF copies available from Sonisys
Recorded price context

The typical recorded price range is $1,211.24 to $1,211.24. Based on 1 archived listing record; not a current offer, appraisal, or confirmed sale price.

View archived listing titles
  • Brooks Instrument GF120X-109489 Mass Flow Controller MFC AMAT 0190-63822 New

Archived listings

Other Part Numbers & Aliases

GF120X-109489Brooks GF120X-109489Brooks Instrument GF120X-109489