Flow Control

GF100-102561

Brooks Instrument GF100 Series Metal-Sealed Thermal Mass Flow Device

About this part

GF100-102561 identifies a Brooks Instrument device in the GF100 standard-performance, non-pressure-transient-insensitive line of high-purity thermal gas-flow devices. The available identifier does not distinguish a controller from a meter or disclose the published long-form configuration code. Gas, calibrated full-scale range, valve configuration, fitting, communications interface, and MultiFlo capability therefore require the physical label or a Brooks build record

Configurations vary. Verify the exact unit before choosing a replacement.

No archived photo available

Key Facts

ManufacturerBrooks Instrument GF100 Series
Part numberGF100-102561
Product familyGF100 Series
Device typeThermal Mass Flow Device
Configuration statusConfiguration varies
Application classSemiconductor/high-purity gas delivery
CategoryFlow Control

Specifications

Identification
ManufacturerBrooks Instrument
Configured identifierGF100-102561
Base modelGF100
Device classMetal-sealed high-purity or ultra-high-purity thermal mass flow controller or meter for gases; the available identifier does not establish whether this unit has a control valve
Performance
GF100 performance classStandard-performance, non-pressure-transient-insensitive model within the GF100 Series
Flow accuracy by communications platformPublished GF100 performance is interface-dependent. Analog/DeviceNet configurations are listed at ±1% of set point over >35-100% full scale and ±0.35% full scale over 2-35%. EtherCAT configurations are listed at ±1% of set point over >20-100% full scale and ±0.2% full scale over 2-20%. Values are based on factory N2 calibration; the installed interface is unverified
Repeatability and reproducibilityPublished GF100 value: ±0.15% of set point over 5-100% full scale and ±0.015% full scale over 2-5%
Settling timeLess than 1 second for a GF100 configuration with a normally closed valve; applicability depends on the installed valve configuration
Pressure-transient insensitivityNot applicable to the GF100 base model; Brooks assigns pressure-transient-insensitive operation to GF125 configurations
Flow
GF100 full-scale range envelope3 sccm to 55 slpm N2 equivalent. This is the published GF100 model envelope, not the verified configured range of GF100-102561
MultiFlo capabilityMultiFlo is selected by the published C configurability option. GF100-102561 does not expose that option, so MultiFlo capability is not established for this unit
Materials
Wetted pathThe GF100 tables specify SEMI F20 HP-compliant wetted materials and list 316L VIM/VAR, Hastelloy C-22, 316L stainless steel, 304 stainless steel, and KM-45. PCTFE is associated only with the optional Zero Leak-by valve
Surface finishThe published GF100 package code specifies 10 µin Ra
Ratings
Operating temperature10-50 °C for standard GF100 configurations
Maximum operating pressure500 psia maximum in the current GF100 specification tables
Controls
Available communications platformsAnalog/RS-485, DeviceNet, and EtherCAT configurations are documented for the GF100 line. The installed platform cannot be determined from GF100-102561
Applications
Application domainThe GF100 Series is intended for semiconductor, MOCVD, thin-film, and other high-purity gas-flow applications

Configuration interpretation

The six-digit suffix is not the long-form option code published in Brooks ordering tables and cannot be used to infer the installed configuration.

What GF100 establishesStandard-performance, non-PTI GF100 model line with a published 3 sccm to 55 slpm N2-equivalent range envelope and 10 µin Ra package definition.
What remains unresolvedController versus meter, gas, calibrated full-scale range, MultiFlo bin or fixed gas/range, valve state, fitting, downstream condition, connector, communications interface, and customer-special settings.
Required configuration evidenceThe unit top and side labels, stored electronic configuration, calibration certificate, or Brooks build record for GF100-102561.

Documentation Downloads

Local PDF copies

Part Photos

0 images

Historical archive images for identification, labels, connectors, and condition reference, not current inventory.

Historical Listings & Prices

Historical listing data, not a current offer
Archive records1Tracked historical listing records
Historical median price$499.00Based on archived listing records
Recorded price range$499.00 - $499.00Low to high recorded listing price
Local documents3PDF copies available from Sonisys
Recorded price context

The typical recorded price range is $499.00 to $499.00. Based on 1 archived listing record; not a current offer, appraisal, or confirmed sale price.

View archived listing titles
  • NEW - BROOKS Instruments Thermal Mass Flow GF Series GF100-102561 280 SCCM - NEW

Archived listings

Other Part Numbers & Aliases

GF100-102561Brooks GF100-102561Brooks Instrument GF100-102561