5850IA1BL3Y2BAA is a configured Brooks Instrument 5850i thermal mass flow controller identifier. Official Brooks 5850i documentation supports the model-level identity as a gas mass flow controller with a flow sensor, control valve, integral electronics, analog command input, and analog output options; exact gas, full-scale range, valve state, fitting, and calibration details remain configured-unit attributes that should be verified from the physical nameplate
Configurations vary. Verify the exact unit before choosing a replacement.
Application classSemiconductor/high-purity gas delivery
CategoryFlow Control
Specifications
Identification
Part identifier
5850IA1BL3Y2BAA
Model platform
Brooks Model 5850i Mass Flow Controller
Device type
Thermal mass flow controller for gases
Function
Control assembly
Flow sensor, control valve, and integral electronic control system
Controls
Command input
Jumper-selectable 0-5 Vdc or 4-20 mAdc command input on the 5850i platform
Signals
Output signal
0-5 Vdc output with jumper-selectable 4-20 mAdc or 0-20 mAdc current output options
Electrical
Power requirement
+15 to +28 Vdc; model manual lists 245 mA at +15 Vdc to 370 mA at +28 Vdc
Connector
15-pin D-type connector, DA-15P
Operating Limits
Working pressure
1500 psi (10.342 MPa) maximum for the 5850i platform
Ambient temperature
Operating 5 to 65 C (40 to 150 F); non-operating -25 to 100 C (-13 to 212 F)
Configuration
Configured-unit rule
Gas, full-scale flow range, fittings, valve configuration, and calibration are configured attributes and should be verified from the unit nameplate or Brooks configuration records