E2-F749-ZFIS-63 is a configured Brooks MT3809 metal tube variable area flowmeter identifier observed in the Sonisys auction archive. Brooks documentation places MT3809 and MT3810 in the all-metal variable-area flowmeter family for gas, liquid, and steam service, with configured materials, connections, electronics, pressure ratings, and temperature limits controlled by the full nameplate/model code
Configurations vary. Verify the exact unit before choosing a replacement.
Application classIndustrial automation and process equipment
CategoryFlow Control
Specifications
Identification
Device type
Metal tube variable area flowmeter
Series family
MT3809G / MT3810G metal tube flowmeter family
Observed configured identifier
E2-F749-ZFIS-63, observed in stored auction titles with Brooks MT3809 and 0-13 m3 flowmeter context
Flow
Measuring principle
Variable area measurement in an all-metal meter body
Applications
Application domain
Gas, liquid, steam, and industrial process flow measurement depending on the configured meter code and process conditions
Materials
Primary meter materials
Brooks lists 316/316L stainless steel as standard for the primary meter, with ETFE-lined and other corrosion-resistant material options available by configuration
Performance
Rangeability
10:1 for most MT3809 / MT3810 meter sizes
Accuracy options
Accuracy class varies by meter type and option; Brooks tables list 1%, 2%, 3%, and 5% options, plus VDI/VDE classes for some configurations
Repeatability
0.25% full scale for standard MT3809 / MT3810 configurations; 1% full scale for some ETFE-lined configurations
Installation
Mounting orientation
Vertical within 5 degrees of true vertical, bottom inlet and top outlet; avoid nearby magnetic interference
Connections
Connection options
Configured flanged and threaded options include ANSI, DIN, and JIS flanges plus NPT/Rc female and NPT male threaded connections, depending on meter version and size
Ratings
Pressure and temperature ratings
Pressure and temperature ratings are configuration-specific and must be read from the applicable Brooks tables and nameplate; family documentation includes flanged, NPT female, and NPT male pressure-rating tables
Temperature
Maximum process temperature
Brooks family documentation lists configurations up to 420 deg C / 788 deg F, with lower limits for some lined, electronic, alarm, and hazardous-area configurations
Electronics
Transmitter options
Available electronics include 4-20 mA / HART 7 transmitter options and Foundation Fieldbus transmitter options, with alarms, pulse output, display, or local operator interface depending on configuration
HART transmitter power
21 to 30 Vdc loop-powered 2-wire transmitter with 3.8 to 22.0 mA loop-current range
Foundation Fieldbus power
9 to 32 Vdc over the 2-wire Foundation Fieldbus connection, with 12 mA current consumption
Controls
Alarm options
Optional high and low flow alarm outputs are available; inductive alarm versions support one or two normally-open inductive limit switches
Protection
Enclosure protection
Brooks documentation lists IP66/67 / NEMA 4X protection categories for configured housing options
Approvals
Hazardous-area and process approvals
Approvals vary by configured electronics and housing; Brooks documentation includes ATEX, IECEx, CSA, UL/cULus, NEMA 4X, CRN, and SIL-related declarations for applicable options
Configuration
Configured-unit rule
Do not treat E2-F749-ZFIS-63 as one universal specification; verify full process size, materials, connection type, transmitter, alarm, pressure, and temperature limits from the nameplate and applicable Brooks documents