Brooks Instrument 1305FL19CJ2CA is a threaded, size-10 Model 1305 variable-area flowmeter configured with a 15 GPM full-scale, direct-reading water scale. Its documented configuration uses an R-10M-75-3 borosilicate metering tube, 10-RJ-120 stainless-steel float, 1-inch female NPT connections, Viton seals, 316 stainless-steel fittings, stainless-steel side plates, and no accessory
Configurations vary. Verify the exact unit before choosing a replacement.
ManufacturerBrooks Instrument Model 1305 / GT130x Series
Part number1305FL19CJ2CA
Product familyConfiguration-specific
Device typeFlowmeter
Configuration statusConfiguration varies
Application classIndustrial automation and process equipment
CategoryFlowmeters
Specifications
Identification
Manufacturer
Brooks Instrument
Model family
Model 1305 / GT130x Series
Base model code
1305F — threaded Model 1305 variable-area flowmeter
Measurement
Measurement principle
Glass-tube variable-area flow indication
Full-scale flow
15 GPM water
Scale calibration
Direct-reading GPM water scale for specific gravity 1.0 and viscosity 1.0 cP
Scale construction
On-tube printed scale
Scale length
75 mm (3 in)
Standard accuracy
±10% of full scale from 100% to 10% of scale reading
Repeatability
1% of full scale
Pressure drop at full-scale water flow
35 in. water column
Configured components
Meter size
Size 10
Metering tube
R-10M-75-3 borosilicate-glass tube
Float
10-RJ-120, 316 stainless steel
Process connections
Connection size and type
1 in. female NPT
Orientation
Vertical inlet and outlet; inlet at bottom and outlet at top
Pressure and temperature
Maximum operating pressure
150 psig (10.3 bar) for the documented size-10, non-CRN configuration
Maximum structural operating temperature
250°F (121°C), subject to process-fluid restrictions in the operating manual
Ambient temperature range
33–125°F (1–52°C)
PED category
SEP
Materials
Process fittings
316 stainless steel
O-rings
Viton fluoroelastomer
Side plates
Stainless steel
Metering tube
Borosilicate glass
Protective sleeve
UV-stabilized polycarbonate
Window
Scratch-resistant, UV-stabilized polycarbonate
Float and float stops
316 stainless steel
Bolts
300-series stainless steel
Physical
Approximate dimensions
7.75 × 2.375 × 2.375 in. (196.85 × 60.33 × 60.33 mm), corresponding to drawing dimensions B × C × D
Approximate weight
1.7 kg (3.8 lb) for the stainless-steel construction
Construction
Seal design
O-ring seal construction
Accessory selection
Code A — none
Family application guidance
Typical Model 1305 services
Purge service, seal-oil systems, bearing lubrication, and cooling-water indication
What Does 1305FL19CJ2CA Mean?
The complete identifier divides into six documented Model 1305 ordering-code segments.
Segment
Field
Interpretation
1305F
Base model
Threaded Brooks Model 1305 glass-tube variable-area flowmeter
L1
Tube designator
Size 10 with R-10M-75-3 metering tube
9C
Float designator
10-RJ-120 float for the size-10 tube; documented in the March 2016 code table
J2
Scale
On-tube GPM water scale for specific gravity 1.0 and viscosity 1.0 cP
C
Materials
316 stainless-steel fittings, Viton O-rings, and stainless-steel side plates
A
Accessories
None
Installation and Safety Notes
Mount the meter within 6 degrees of true vertical, with the inlet at the bottom and outlet at the top.
Support the process piping so it does not impose undue strain on the flowmeter.
Keep the protective sleeve installed, secure the meter windows, avoid pressure and flow surges, and never service the meter while pressurized.
The 250°F (121°C) rating is a structural family limit. The manual specifically prohibits water above 140°F, steam, alkalis, fluorine, hydrofluoric acid, molten metal, toxic fluids, and fluids that react chemically with glass.
Drain an isolated liquid-filled meter in a bypass loop to prevent glass-tube breakage from thermal expansion.
Install new inlet and outlet O-rings whenever the meter is removed for service, then hydrostatically pressure-test it before returning it to operation.
Replacement and Retrofit Guidance
The June 2026 Brooks GT1600 data sheet identifies the GT1600 Series as configurable for GT1300-family retrofits and provides a dedicated 1305 vertical-inlet/vertical-outlet retrofit dimension of 7.75 in. (196.9 mm). This establishes a manufacturer-supported retrofit path, but not a universal one-for-one replacement for 1305FL19CJ2CA. A replacement must be selected for the required 15 GPM water range, process materials, pressure and temperature limits, connection orientation, and installation geometry.