Flow Measurement

1020CZ10

Brooks GT1000 Glass-Tube Variable-Area Flowmeter

About this part

1020CZ10 identifies an observed Brooks GT1000 industrial glass-tube variable-area flowmeter. The GT1000 uses a tapered borosilicate-glass tube and float for visual gas or liquid flow measurement and was offered with configurable tube sizes, floats, scales, process connections, alarms, seals, and fitting materials. The short 1020CZ10 identifier does not conform to the complete model-code format in the final Brooks GT1000 literature, so its unit-specific options must be confirmed from the instrument nameplate, scale, and construction rather than inferred from the later code table

Configurations vary. Verify the exact unit before choosing a replacement.

Key Facts

ManufacturerBrooks Instrument GT1000 Series
Part number1020CZ10
Product familyConfiguration-specific
Device typeFlowmeter
Configuration statusConfiguration varies
Application classIndustrial automation and process equipment
CategoryFlow Measurement

Specifications

Identification
ManufacturerBrooks Instrument
Product familyGT1000 Series
Part identifier1020CZ10
Product statusLegacy product family
Measurement
Measuring principleVariable area; a float rises within a vertically mounted tapered glass tube as flow increases
Performance — GT1000 family
Standard flow accuracy±2% of full scale; Class 2.5 per VDI/VDE
Optional flow accuracy±1% of full scale; Class 1.6 per VDI/VDE
Repeatability≤0.5% of full scale
Environmental — GT1000 family
Ambient temperature33 to 125°F (1 to 52°C)
Operating-fluid temperature33 to 250°F (1 to 121°C); configured alarm limits may be lower
Construction — GT1000 family
Metering tubeBorosilicate glass
WindowPolycarbonate with UV inhibitor
HousingEpoxy-painted cast aluminum
End-fitting optionsBrass or 316/316L stainless steel
O-ring optionsViton fluoroelastomer, Buna-N, Kalrez perfluoroelastomer, or EPDM; availability depends on fitting material
Configuration — GT1000 family
Scale optionsSingle or dual detachable aluminum scale; nominal lengths 127, 200, or 250 mm; direct-reading, millimeter, or percent graduations
Process-connection optionsNPT or Rc/BSPT female threads, or ANSI B16.5 Class 150 raised-face flanges
Pressure — GT1000 family
Maximum non-shock pressure range75 to 500 psig (5.2 to 34.5 bar), depending on tube size and threaded or flanged connection; this range is not an exact 1020CZ10 rating

Identifier and model-code boundary

Brooks' April 2018 GT1000 data sheet publishes a 16-field ordering code beginning with 1020N, 1024N, 1026N, or 1027N. The shorter 1020CZ10 identifier lacks the documented base-model suffix and contains characters that cannot be placed reliably into that later format. It should therefore be retained as the exact observed legacy identifier without assigning an exact tube, float, alarm, seal, fitting, connection, scale, or accuracy option from the 2018 code table.

Published GT1000 connection-orientation codes

These manufacturer-published codes describe the later GT1000 ordering system and provide family context; they are not exact aliases for 1020CZ10.

Published base modelInlet orientationOutlet orientation
1020NHorizontalHorizontal
1024NVerticalVertical
1026NHorizontalVertical
1027NVerticalHorizontal

Replacement relationship

Brooks identifies the GT1600 as the replacement family for legacy GT1000 meters, with retrofit configurations available for existing installations. Replacement selection remains configuration-dependent.

Legacy familyGT1000 Series
Manufacturer-designated replacement familyGT1600 Series
Compatibility boundaryGT1600 can be configured to retrofit GT1000 installations; tube range, process connections, orientation, scale, alarms, valve, materials, and dimensions must be matched

Safety and installation essentials

The glass metering tube is a pressure-containing component and requires the precautions specified by Brooks.

Documentation Downloads

Local PDF copies

Part Photos

5 images

Historical archive images for identification, labels, connectors, and condition reference, not current inventory.

Historical Listings & Prices

Historical listing data, not a current offer
Archive records1Tracked historical listing records
Historical median price$112.00Based on archived listing records
Recorded price range$112.00 - $112.00Low to high recorded listing price
Local documents3PDF copies available from Sonisys
Recorded price context

The typical recorded price range is $112.00 to $112.00. Based on 1 archived listing record; not a current offer, appraisal, or confirmed sale price.

View archived listing titles
  • Brooks GT 1000 Variable Area Flow meter 1020CZ10 240psig at 150º

Archived listings

Other Part Numbers & Aliases

1020CZ10Brooks 1020CZ10Brooks Instrument 1020CZ10