Flow Control

UKQ68

Brooks Instrument 0154E Four-Channel Secondary Electronics — Record

About this part

UKQ68 is an auction inventory identifier associated with a Brooks Instrument 0154E four-channel secondary-electronics unit; it is not a verified Brooks model or part number. The 0154E supplies power to compatible flow or pressure devices, displays process values, and provides setpoint, blending, valve-override, local/remote, and RS-232 control functions. Brooks has discontinued the 0152/0154 devices and identifies the 0250 Series as their replacement

Configurations vary. Verify the exact unit before choosing a replacement.

No archived photo available

Key Facts

ManufacturerBrooks Instrument 0154 Series
Part numberUKQ68
Product familyConfiguration-specific
Device typeController
Configuration statusConfiguration varies
Application classIndustrial automation and process equipment
CategoryFlow Control

Specifications

Identification
ManufacturerBrooks Instrument
Observed equipment model0154E
UKQ68 identifierAuction inventory identifier; not verified as a Brooks manufacturer part number
Product family0152/0154 gas and liquid mass-flow secondary electronics
Functional
ChannelsFour channels for Model 0154
Connected-device functionsPower, readout, setpoint control, blending, valve override, and local/remote operation for compatible mass-flow or pressure devices
Channel operationIndependent operation or master/slave blending; each channel can be configured as master, slave, or independent
Display
DisplayBacklit 4 × 20-character display for Model 0154
Displayed valuePercentage of full scale or a configured process reading
Performance
Readout and control accuracy0.1% of the configured maximum flow value
Electrical
Operating power input90–260 Vac, 50/60 Hz, 70 W maximum; the manual's safety-approval scope separately lists 100–240 Vac, 50/60 Hz, 100 W
Device power output+15 Vdc at 2.9 A and −15 Vdc at 1.4 A maximum, or +24 Vdc at 2.5 A maximum, depending on configuration
Analog signal ranges0–5 Vdc, 1–5 Vdc, 0–20 mA, or 4–20 mA; current I/O requires the optional I/O board
Signal output loadingVoltage-output load impedance at least 1 kΩ; current-output load impedance at most 750 Ω
Connections
Device channelsFour 15-pin D-sub connectors on Model 0154
Remote setpoint and flow interfaceOne 25-pin D-sub connector serving up to four channels
External valve overrideOne 15-pin D-sub connector
Communications
Computer interfaceOne 9-pin RS-232 D-sub connector
Mechanical
HousingAnodized-aluminum housing with steel covers; half-width 19-inch rack cassette, rack, panel, or tabletop arrangements
Cassette dimensions130 × 220 × 230 mm (5.1 × 8.7 × 9.1 in), height × width × depth
Environmental
Ambient operating temperature0–50 °C (32–122 °F)
Safety-approval environmentIndoor use; altitude to 2,000 m; Pollution Degree 2; Installation Category II; maximum relative humidity 80%
Lifecycle
Manufacturer availabilityDiscontinued and no longer offered for sale; superseded by the Brooks 0250 Series

Identifier interpretation

The record identifier and the equipment model should remain distinct.

Sonisys record identifierUKQ68
Observed Brooks model0154E
Manufacturer identifier judgmentNo Brooks documentation identifies UKQ68 as a model, ordering code, or service part number.

Replacement and software support

Brooks continues to document software support for the legacy equipment while directing new applications to the 0250 Series.

Legacy product statusModels 0152 and 0154 are no longer offered for sale.
Manufacturer-designated replacement0250 Series; Model 0254 is the four-channel successor.
Enclosure retrofitThe 0250 Series rack-mount kit can adapt a Model 0254 and its power supply to the tabletop enclosure formerly used by Models 0152/0154.
Supported softwareBrooks Smart DDE and Brooks LabVIEW DLL documentation continue to list Models 0152 and 0154.

Channel connector pinout

Family-manual pinout for each 15-pin channel connector. Available supply rails and analog functions depend on the ordered electrical configuration.

PinDirectionFunction
1Output+15 Vdc or +24 Vdc
2InputFlow current signal
3OutputCurrent setpoint
4—Not connected
5OutputVoltage setpoint
6—Setpoint ground
7OutputValve override
8—Flow-signal ground
9—Reserved
10InputFlow voltage signal
11—Not connected
12—Power ground
13Output+15 Vdc or +24 Vdc
14Output−15 Vdc or not connected
15—Not connected

Configuration and compatibility boundary

The 0154 family was configurable, so the nameplate and rear connections govern service compatibility for an individual unit.

Installation and service notes

Key requirements from the Brooks family manual.

Documentation Downloads

Local PDF copies

Part Photos

0 images

Historical archive images for identification, labels, connectors, and condition reference, not current inventory.

Historical Listings & Prices

Historical listing data, not a current offer
Archive records2Tracked historical listing records
Historical median price$437.50Based on archived listing records
Recorded price range$375.00 - $500.00Low to high recorded listing price
Local documents4PDF copies available from Sonisys
Recorded price context

The typical recorded price range is $387.50 to $487.50. Based on 2 archived listing records; not a current offer, appraisal, or confirmed sale price.

View archived listing titles
  • BROOKS INSTRUMENT 4 CHANNEL 0154E - MASS FLOW CONTROLLER (UKQ68)

Archived listings

Other Part Numbers & Aliases