Pressure Control

SLA7840AZ622

Brooks Analog Remote-Transducer Pressure/Flow Controller

About this part

Brooks SLA7840AZ622 is an analog SLA7840 remote-transducer controller. It uses an external pressure-transducer signal and adjustable PID electronics to regulate pressure with an integral co-planar valve while independently measuring mass flow. The A code establishes the analog interface; the undocumented Z622 suffix does not establish the configured gas, calibrated range, process connection, valve sizing, or control direction

Configurations vary. Verify the exact unit before choosing a replacement.

Key Facts

ManufacturerBrooks Instrument SLA7840
Part numberSLA7840AZ622
Product familySLA7840 Series
Device typeController
Configuration statusConfiguration varies
Application classIndustrial automation and process equipment
CategoryPressure Control

Specifications

Identification — Exact Identifier
ManufacturerBrooks Instrument
Base modelSLA7840A
Device typeHigh-purity, metal-sealed remote-transducer pressure/flow controller
Controls — Exact A Variant
InterfaceAnalog I/O
Electrical connector15-pin male D-sub connector
Setpoint input0–5 Vdc; accepts up to 5.5 Vdc, corresponding to 110% full scale
Flow output0–5 Vdc into a minimum 2 kΩ load; indication extends to 5.5 Vdc
Remote pressure-sensor input0–10 Vdc; accepts up to 10.2 Vdc; 480 kΩ nominal input resistance
Power supply+15 Vdc ±5%; the traditional −15 Vdc pin is ignored
Power requirement3.6 W typical, 4.0 W maximum
Operating-mode selectionMode-select pin 13 open: flow-control mode; pin 13 connected to signal common pin 10: pressure-control mode
Secondary-electronics compatibilityBrooks Model 0254 Series
SLA7840 Family Performance
Available full-scale flow rangesAny range from 0–3 sccm through 0–30,000 sccm, nitrogen equivalent; exact configured range is not decoded by Z622
Flow control range33:1
Flow accuracy±1.0% of rate from 20% to 100% full scale; ±0.2% of full scale below 20% full scale
Flow repeatability±0.20% of rate
Flow settling timeLess than 1 second to within ±2% of full scale for a 0–100% step
Pressure rangeDetermined by the remote pressure transducer; 500 psig maximum
Pressure control range20:1
Pressure settling timeLess than 1 second typical for a 20–100% setpoint step with no more than 2% overshoot; actual response is system-dependent
SLA7840 Family Ratings
Maximum operating pressure500 psig
Leak integrityInboard-to-outboard helium leakage no greater than 1 × 10^-10 atm-scc/s
Ambient temperatureOperating: 0–60°C; non-operating: −25–100°C
Fluid temperature0–65°C
SLA7840 Family Construction
Mechanical platform1-1/8-inch-wide body
Valve technologyCo-planar control valve
Wetted materials316L vacuum-arc-remelt stainless steel, 316L stainless steel, and high-alloy ferritic stainless steel
Seals and standard valve seatNickel internal/external seals; standard 316L stainless-steel valve seat
Wetted surface finish32 µin Ra maximum
Process-connection choicesStandard 1/4-inch male VCR; C Seal, CS Seal, and W Seal were also offered. Z622 does not identify the exact connection
SLA7840 Family Capabilities
Stored calibrationsUp to 10 selectable gas calibrations and flow ranges

What Does SLA7840AZ622 Mean?

The published model definition supports the SLA7840 and A segments. The remaining suffix requires a nameplate, calibration record, factory order record, or Brooks configuration record for further decoding.

SegmentFieldInterpretation
SLA7840Product platformHigh-purity, metal-sealed remote-transducer pressure/flow controller with integral mass-flow measurement
AElectrical I/O variantAnalog interface using a 15-pin male D-sub connector, 0–5 Vdc setpoint and flow signals, and a +15 Vdc supply
Z622Configuration suffixNot defined in the available manufacturer publications; do not assert gas, calibrated range, process connection, valve sizing, control direction, or customer option from this suffix alone

Configuration and Service Notes

Documentation Downloads

Local PDF copies

Part Photos

4 images

Historical archive images for identification, labels, connectors, and condition reference, not current inventory.

Historical Listings & Prices

Historical listing data, not a current offer
Archive records1Tracked historical listing records
Historical median price$140.00Based on archived listing records
Recorded price range$140.00 - $140.00Low to high recorded listing price
Local documents2PDF copies available from Sonisys
Recorded price context

The typical recorded price range is $140.00 to $140.00. Based on 1 archived listing record; not a current offer, appraisal, or confirmed sale price.

View archived listing titles
  • Brooks Delta Class Smart Mass Flow Controller MFC Gas AR SLA7840AZ622

Archived listings

Other Part Numbers & Aliases

SLA7840AZ622Brooks SLA7840AZ622Brooks Instrument SLA7840AZ622