Flow Control
QMBS4L1A3D1A1CM2C1A1E
Brooks Instrument Quantim QMBS4 Modbus Coriolis Mass Flow Sensor
About this part
Brooks Instrument QMBS4L1A3D1A1CM2C1A1E is a Quantim QmBS4 Coriolis mass flow sensor with Modbus RS-485 output. Its supported model-code prefix specifies the large tube size, liquid as the primary fluid type, no pressure transducer, no valve, 0.5% liquid-flow accuracy with a 316L sensor tube, and a NEMA 4X/IP65 hazardous-area enclosure. Published QmBS4 performance is 13.5 kg/hr nominal and 27 kg/hr maximum for liquids. The supplied identifier omits positions required by the published full ordering-code format; its pressure rating, process connection, seals, certifications, filter, and OEM option are therefore not asserted
Configurations vary. Verify the exact unit before choosing a replacement.
No archived photo available
Key Facts
Specifications
| Manufacturer | Brooks Instrument |
| Product family | Quantim QmBS |
| Base model | QMBS flow sensor with Modbus RS-485 output |
| Measuring principle | Direct Coriolis mass-flow measurement |
| Tube size | 4 — large sensor |
| Primary fluid type | Liquid; switching to gas is permitted after rezeroing |
| Pressure transducer | None |
| Valve | None; measurement-only sensor |
| Specified mass-flow accuracy | ±0.5% of rate or ±[(zero stability ÷ flow rate) × 100]% of rate, whichever is greater |
| Enclosure and area classification | NEMA 4X/IP65; Class I, Division 2/Zone 2 |
| Surface finish | Standard, 32 Ra |
| Sensor tube material | 316L stainless steel |
| Nominal liquid flow | 13.5 kg/hr (29.77 lb/hr) |
| Maximum liquid flow | 27 kg/hr (59.54 lb/hr) |
| Typical gas flow | 3.640 kg/hr; 50,350 sccm on air at stated reference conditions |
| Zero stability | 0.0040 kg/hr (0.0088 lb/hr) with stainless-steel sensor tube |
| Mass-flow repeatability | ±0.05% of rate or ±[0.5 × (zero stability ÷ flow rate) × 100]% of rate, whichever is greater |
| Density range | 0–0.3 and 0.5–2.0 g/cm³; consult Brooks for 0.3–0.5 g/cm³ |
| Density accuracy and repeatability | Accuracy ±0.005 g/cm³; repeatability ±0.002 g/cm³ |
| Ambient and process temperature | 0–65°C (32–149°F); device-temperature accuracy ±0.5°C (±1.0°F) |
| Documented wetted materials | 316/316L stainless steel; the configured sensor-tube code specifies 316L stainless steel |
| Housing | Polyurethane-painted aluminum and stainless steel |
What Does QMBS4L1A3D1A1CM2C1A1E Mean?
The published June 2006 ordering table supports the leading fields shown below. The remaining compact suffix cannot be aligned conservatively with every required field.
| Segment | Field | Interpretation |
|---|---|---|
| QMBS | Base model | Quantim flow sensor with Modbus RS-485 output |
| 4 | Tube size | Large sensor; 13.5 kg/hr nominal liquid flow |
| L | Primary fluid type | Liquid; liquid/gas switching requires rezeroing |
| 1 | Pressure transducer | No transducer |
| A | Valve type | No valve |
| 3 | Accuracy | Optional 0.5% of rate for liquid measurement with stainless-steel sensor tube |
| D | Enclosure and area classification | NEMA 4X/IP65; Class I, Division 2/Zone 2 |
| 1 | Surface finish | Standard, 32 Ra |
| A | Sensor tube material | 316L stainless steel |
| 1CM2C1A1E | Remaining suffix | Not positionally complete under the published full model-code revision; no further exact options are asserted |
Tube Size 4 Flow Capability
Flow limits depend on the process fluid and stated reference conditions.
| Medium | Documented flow | Reference basis |
|---|---|---|
| Liquid | 13.5 kg/hr nominal; 27 kg/hr maximum | Water at reference conditions; volumetric values assume density of 1 g/cm³ |
| Gas | 3.640 kg/hr; 50,350 sccm typical | Air at 70°F, 500 psia inlet, and approximately 1 bar pressure drop |
Compatibility and Replacement
Brooks classifies the QMB series as legacy and directs customers to the current Quantim QMC family.
Documentation Downloads
Local PDF copiesPart Photos
0 imagesHistorical archive images for identification, labels, connectors, and condition reference, not current inventory.
Historical Listings & Prices
Historical listing data, not a current offerThe typical recorded price range is $499.00 to $499.00. Based on 1 archived listing record; not a current offer, appraisal, or confirmed sale price.
View archived listing titles
- BROOKS INSTRUMENT QUANTIM QMBS4L1A3D1A1CM2C1A1E PRECISION MASS FLOW 500PSI/35BAR