Flow Control

DSWK1YY

Brooks / Mykrolis IntelliFlow II Digital Mass Flow Controller

About this part

DSWK1YY identifies an IntelliFlow II digital mass flow controller. Its documented prefix specifies a normally closed controller with a stainless-steel body and Hastelloy sensor. The identifier is one character shorter than the published eight-position hardware ordering code, so the configured flow range, fitting, electrical interface, firmware revision, and special options require verification from the complete rear label

Configurations vary. Verify the exact unit before choosing a replacement.

No archived photo available

Key Facts

ManufacturerBrooks / Mykrolis IntelliFlow II
Part numberDSWK1YY
Product familyConfiguration-specific
Device typeMass Flow Controller
Configuration statusConfiguration varies
Application classIndustrial automation and process equipment
CategoryFlow Control

Specifications

Identification
Model familyIntelliFlow II
Configuration
Product-code prefixDS
Product functionMass flow controller
Valve configurationNormally closed, diaphragm-isolated solenoid valve
Materials
Body and sensor codeStainless-steel body with Hastelloy sensor
Family specifications
Published flow-bin coverage1 to 100,000 sccm N₂ equivalent; configured-unit range not established
Available communications0–5 VDC analog, RS-485 digital, or optional DeviceNet, depending on configuration
Operating temperature0 to 50 °C ambient and gas
Humidity10% to 95% RH, non-condensing
Maximum overrange pressure140 psig (9.5 bar)
External leak integrityLess than 1 × 10⁻¹⁰ atm·cc/s
Turndown ratio50:1

What Does DSWK1YY Mean?

Only positions that remain unambiguous under the published IntelliFlow II ordering structure are decoded.

SegmentFieldInterpretation
DProductMass flow controller with normally closed valve
SMaterialsStainless-steel body with Hastelloy sensor
WK1YYRemaining configurationCannot be mapped safely because DSWK1YY contains seven characters while the published hardware code uses eight positions. The complete rear-label code is required to establish flow range, fittings, interface, firmware, and options.

Published IntelliFlow II Performance Bands

These are family-level PF2033 Rev. G values, not confirmed DSWK1YY configured-unit ratings. The later A331749 Rev. 001 guide describes the 30–100 slpm specifications as tentative pending final qualification.

Parameter≤30 slpm N₂ equivalent30–100 slpm N₂ equivalent
Turndown ratio50:150:1
Response/settling time1 second typicalLess than 2.5 seconds
Analog accuracy±(0.25% SP + 0.50% FS)±(1.0% SP + 0.50% FS)
Digital accuracy±(0.25% SP + 0.35% FS)±(1.0% SP + 0.35% FS)
Linearity±0.50% FS maximum±0.75% FS maximum
Repeatability±0.15% FS maximum±0.25% FS maximum
Differential pressure7–40 psid through 11 slpm; 15–40 psid from 11–30 slpm30–50 psid

Configuration Label Interpretation

Rear labelShows the calibration gas and range.
Top labelShows the programmed gas and range and may be customer-configurable.
Replacement verificationConfirm both labels and the complete rear-label model number before matching gas, range, fittings, or electrical interface.

Documentation Downloads

Local PDF copies

Part Photos

0 images

Historical archive images for identification, labels, connectors, and condition reference, not current inventory.

Historical Listings & Prices

Historical listing data, not a current offer
Archive records1Tracked historical listing records
Historical median price$490.00Based on archived listing records
Recorded price range$490.00 - $490.00Low to high recorded listing price
Local documents2PDF copies available from Sonisys
Recorded price context

The typical recorded price range is $490.00 to $490.00. Based on 1 archived listing record; not a current offer, appraisal, or confirmed sale price.

View archived listing titles
  • BROOKS Mykrolis Intelli Flusso II Digitale Flusso Controller Tipo DSWK1YY Gas N2

Archived listings

Other Part Numbers & Aliases

DSWK1YYBrooks DSWK1YYMykrolis DSWK1YY