Flow Control

DN40

Brooks Instrument MT 3819 Metal-Tube Variable-Area Flowmeter

About this part

Brooks MT 3819 DN40 identifies the size-12, 1-1/2-inch flanged version of the MT 3819 variable-area flowmeter. DN40 is a nominal connection-size designation, not a complete Brooks order number. The MT 3819 uses an ETFE-lined stainless-steel metering tube for aggressive liquid and gas service, with configurations determined by the complete model code

Configurations vary. Verify the exact unit before choosing a replacement.

No archived photo available

Key Facts

ManufacturerBrooks Instrument MT 3819
Part numberDN40
Product familyMT3819 Series
Device typeFlowmeter
Configuration statusConfiguration varies
Application classIndustrial automation and process equipment
CategoryFlow Control

Specifications

Identification
ManufacturerBrooks Instrument
Product familyMT 3819
Meaning of DN40Nominal connection size; Brooks meter size 12 with 1-1/2-inch flanged connections
Measurement
Measuring principleMetal-tube variable-area measurement with magnetically coupled dial indication
Process
Documented serviceAggressive liquids and gases
Construction
Standard metering tube316L stainless steel with ETFE (Tefzel) lining
Standard flanges and end fittings316L stainless steel
Standard float for meter size 12PVDF
Performance
Standard flow accuracy±2% of full scale in the North American data sheet; European configurations use VDI/VDE accuracy classes
Optional flow accuracy±1% of full scale
Repeatability0.25% of full scale
Capacity
DN40 water capacity choices3,000, 4,000, 5,000 or 6,000 l/h nominal maximum, according to float code A, B, C or D
DN40 air capacity choices55, 74, 92 or 110 scfm at 70°F and 14.7 psia; 87, 110, 140 or 170 Nm³/h at 0°C and 1.013 bar(a)
DN40 pressure-drop choices50, 75, 85 or 120 mbar, according to float code
Operating limits
Tefzel-lined gas-service pressureOperating pressure must exceed 29 psia / 2 bar(a)
Maximum process-fluid temperature150°C; actual limit remains subject to indicator electronics, ambient temperature and hazardous-area approval
Connections
Documented flange typesANSI 150 RF, ANSI 300 RF or DIN PN40 RF, depending on model code
Installation
OrientationVertical, inlet at bottom and outlet at top; install within 5° of true vertical
Dimensions
Flanged face-to-face length250 mm for meter size 12
Enclosure
Indicator housingNEMA 4X construction; inductive-alarm documentation specifies Type 4X / IP65

What Does DN40 Mean?

DN40 defines the nominal process-connection size rather than the complete flowmeter configuration.

SegmentFieldInterpretation
DNNominal diameterMetric nominal pipe-size designation
40Nominal sizeBrooks maps DN40 to meter size 12 with 1-1/2-inch flanged connections

Observed Brooks Model Code 3819B14BAHBD1A1

This archived full model code represents one configured DN40 meter. Its range, scale, alarm and power-supply selections do not apply to all DN40 units.

SegmentFieldInterpretation
3819/BBasic modelMetal-tube flowmeter with vertical inlet and outlet
1Material316L stainless steel with ETFE lining
4Meter and connection sizeMeter size 12; DN40 / 1-1/2-inch flanged
BFloat/capacity optionNominal maximum water capacity 4,000 l/h; corresponding tabulated air capacity 74 scfm / 110 Nm³/h
AConnectionANSI 150-pound RF flange
HAccuracy, scale and fluidVDI/VDE Class 2.5, direct-reading liquid scale
BIndicatorStandard aluminum indicator with one Pepperl+Fuchs inductive alarm switch
DRelay/power supplyOne-channel intrinsically safe relay/power-supply unit, 115 VAC
1Certification optionNone
AAccessory optionNone
1Software revisionNone / not applicable because no microprocessor transmitter is selected

Legacy and Current Nomenclature

Current Brooks MT3809-series literature lists a TFE-lined configuration with substantially similar Tefzel-lined construction and size tables, while the legacy documents identify this product as MT 3819. Similar family characteristics do not establish a drop-in replacement. Replacement selection requires confirmation of capacity, calibration fluid, flange standard and pressure class, wetted materials, alarm electronics, approvals and face-to-face dimensions.

Documentation Downloads

Local PDF copies

Part Photos

0 images

Historical archive images for identification, labels, connectors, and condition reference, not current inventory.

Historical Listings & Prices

Historical listing data, not a current offer
Archive records1Tracked historical listing records
Historical median price$328.63Based on archived listing records
Recorded price range$328.63 - $328.63Low to high recorded listing price
Local documents2PDF copies available from Sonisys
Recorded price context

The typical recorded price range is $328.63 to $328.63. Based on 1 archived listing record; not a current offer, appraisal, or confirmed sale price.

View archived listing titles
  • Brooks Metal Tube Variable Area Flowmeter MT 3819 DN40 3819B14BAHBD1A1 1-1/2"

Archived listings

Other Part Numbers & Aliases

DN40MT 3819 DN40MT3819 DN40