Brooks Instrument Sho-Rate 1355E Variable Area Flowmeter
About this part
1355EE2BCFG5LM is a configured Brooks Instrument Sho-Rate 150 / Model 1355E glass tube variable-area flowmeter. Official Brooks 1350E/1355E documentation identifies 1355E as the 150 mm Sho-Rate family and provides the model-code table used to decode this configured code as an E-series 1355E meter with an R-2-15-C tube, stainless steel float, special single scale, Viton tube packing and O-rings, 316 stainless steel threaded 1/8 in. NPT fittings with locknuts, a 316 stainless steel high-flow standard valve on the outlet, and stainless side-plate and spring-float-stop accessory selections. Stored Sonisys auction records identify this exact code as a Brooks Sho-Rate 1355E flow meter and include 200 psi / 250 F context; exact installed scale range and service fluid should still be verified from the physical scale and label
Configurations vary. Verify the exact unit before choosing a replacement.
Application classIndustrial automation and process equipment
CategoryFlow Control
Specifications
Identification
Device type
Glass tube variable-area flowmeter / rotameter
Series family
Brooks Sho-Rate 1350E / 1355E family
1355E family name
Sho-Rate 150
Configured model code
1355EE2BCFG5LM
Function
Measuring principle
Variable area flow indication using a tapered glass metering tube and metering float
Scale
1355 series scale length
150 mm nominal
Scale option decoded from code E2B
Special single scale with standard 1355 accuracy context; exact fluid and range are unit-specific and must be read from the installed scale
Flow path
Tube and float decoded from code E2B
R-2-15-C tube with stainless steel float
Performance
1355 Series accuracy
Brooks 1350E/1355E documentation lists 1355 Series standard accuracy as +/-5% full scale
Repeatability
Brooks 1350E/1355E documentation lists repeatability as 0.5% full scale
Pressure and temperature
Family pressure and temperature rating
Brooks 1350E/1355E documentation lists 200 psig from 33 F to 250 F / 1 C to 121 C, and 170 psig over the same temperature range when supplied under CRN certification
Construction
Metering tube material
Borosilicate glass
Packing and seals decoded from code C
Viton tube packing with Viton O-rings
Fitting and connection decoded from code F
316 stainless steel threaded 1/8 in. NPT fittings with locknuts
Controls
Valve decoded from code G
Standard 316 stainless steel high-flow valve
Valve location decoded from code 5
Outlet valve cavity location with in-back / out-back standard connection orientation
Accessories
Accessory codes
Code L indicates stainless steel side plates; code M indicates stainless steel spring float stops
Installation
Orientation
Install within 6 degrees of true vertical with inlet connection at the bottom end fitting
Configuration
Configured-unit rule
Special scale fluid, direct-reading range, calibration basis, condition of the glass tube and float, valve condition, seals, and process suitability must be verified from the physical unit
Observed variants
Stored auction context
Stored Sonisys title evidence identifies this exact configured code as a Brooks Sho-Rate 1355E Series flow meter and includes 200 psi / 250 F wording
Applications
Application domain
Low-flow gas and liquid indication, purge flow service, panel-mounted rotameter applications, and configured flow-control assemblies where the unit's materials and calibration match the process