1350GAM3BBNG1AAA is a configured Brooks Instrument Sho-Rate 1350G glass tube variable-area flowmeter. Official Brooks 1350G/1355G documentation identifies the 1350G as a 65 mm Sho-Rate flow indicator, and the model-code table decodes this configuration as a Revision G unit with 316 stainless steel end blocks, R-6-65-B G tube, stainless steel float with custom decal scale, Viton packing and O-rings, 316 stainless steel 1/4 in NPT threaded end fittings with locknuts, NRS #6 316 stainless steel valve, inlet/back-back valve orientation, no alarms, no additional listed option, and no listed certification option. Exact scale markings, fluid, and calibrated range should still be verified from the physical unit label and scale
Configurations vary. Verify the exact unit before choosing a replacement.
Application classIndustrial automation and process equipment
CategoryFlow Control
Specifications
Identification
Device type
Glass tube variable-area flowmeter
Series family
Brooks Sho-Rate 1350G/1355G Series
Configured model code
1350GAM3BBNG1AAA
Base model
1350G, a 65 mm Sho-Rate size 1-6 flow indicator in Brooks model-code documentation
Flow
Measuring principle
Variable-area rotameter with tapered borosilicate glass metering tube and metering float
Decoded tube code
Model-code position VII M decodes to R-6-65-B G for a 1350G meter
Decoded float and scale selection
Model-code positions VIII-IX 3B decode to stainless steel float with standard 1350 custom decal scale selection
Official full-scale air context for decoded tube and float
For 1350G tube R-6-65-B G with stainless steel float, Brooks documentation lists 86 SCFH air full scale at stated reference conditions
Official full-scale water context for decoded tube and float
For 1350G tube R-6-65-B G with stainless steel float, Brooks documentation lists 20 GPH / 76 LPH water full scale
Performance
1350G accuracy context
Brooks documentation lists Model 1350G accuracy as +/-5% at reference conditions; custom scale and calibration details remain unit-specific
Repeatability
Brooks documentation lists repeatability as 0.25% full scale
Pressure / Temperature
Series pressure and temperature rating
Brooks 1350G/1355G documentation lists 200 psig from 33 F to 250 F / 13.8 bar from 1 C to 121 C
Construction
Decoded end block material
Model-code position VI A decodes to 316 stainless steel
Decoded packing and O-ring materials
Model-code position X B decodes to Viton tube packing and Viton meter/valve O-ring material
Connections
Decoded end fitting and connection
Model-code position XI N decodes to 316 stainless steel 1/4 in NPT threaded end fittings with locknut
Controls
Decoded valve type
Model-code position XII G decodes to NRS #6 valve in 316 stainless steel
Decoded valve/controller location
Model-code position XIII 1 decodes to inlet location with back inlet and back outlet connection orientation
Options
Decoded alarms
Model-code position XIV A decodes to no alarm option
Decoded additional option
Model-code position XV A decodes to no additional listed option
Decoded certification option
Model-code position XVI A decodes to no additional certification option
Installation
Mounting orientation
Brooks installation documentation describes the Sho-Rate flowmeter as a vertically mounted variable-area meter with bottom-to-top flow
Configuration
Configured-unit rule
Tube, float, scale, process fluid, operating range, valve, seals, connections, options, and calibration context are model-code and unit-label specific
Observed variants
Stored auction identity context
Stored Sonisys auction records identify this exact configured code as a Brooks Instrument Sho-Rate flow meter and include a 200 psig at 250 F listing context