1350GAL3AAJU5ARA is a configured Brooks Instrument Sho-Rate 1350G glass tube variable-area flowmeter. Official Brooks 1350G/1355G documentation identifies the 1350G as a 65 mm Sho-Rate flow indicator and its model-code table decodes this configuration as a 316 stainless steel end-block unit with an R-6-65-A G tube, glass float custom-decal scale, Buna packing and O-ring materials, 316 stainless steel 1/4 in NPT end fittings, a medium-flow 316 stainless steel Cartridge III valve, outlet/back-back valve orientation, no alarms, stainless steel tag option, and no listed certification option. Exact scale markings and calibrated range should still be verified from the physical unit label and scale
Configurations vary. Verify the exact unit before choosing a replacement.
Application classIndustrial automation and process equipment
CategoryFlow Control
Specifications
Identification
Device type
Glass tube variable-area flowmeter
Series family
Brooks Sho-Rate 1350G/1355G Series
Configured model code
1350GAL3AAJU5ARA
Base model
1350G, a 65 mm Sho-Rate flow indicator in Brooks model-code documentation
Flow
Measuring principle
Variable-area rotameter with tapered glass metering tube and metering float
Decoded tube code
Model-code position VII L decodes to R-6-65-A G for a 1350G meter
Decoded float and scale selection
Model-code positions VIII-IX 3A decode to glass float with custom decal scale
Official full-scale air context for decoded tube and float
For 1350G tube R-6-65-A G with glass float, Brooks documentation lists 13 SCFH air full scale at standard reference conditions
Official full-scale water context for decoded tube and float
For 1350G tube R-6-65-A G with glass float, Brooks documentation lists 2.2 GPH / 8.5 LPH water full scale
Performance
1350G accuracy context
Brooks documentation lists Model 1350G accuracy as +/-5% at reference conditions for calibrated scales and +/-10% for standard 50 mm scales; the exact scale type should be checked on the unit
Repeatability
Brooks documentation lists repeatability as 0.25% full scale
Pressure / Temperature
Series pressure and temperature rating
Brooks 1350G/1355G documentation lists 200 psig from 33 F to 250 F / 13.8 bar from 1 C to 121 C
Construction
Decoded end block material
Model-code position VI A decodes to 316 stainless steel
Decoded packing and O-ring materials
Model-code position X A decodes to Buna tube packing and Buna meter/valve O-ring material
Connections
Decoded end fitting and connection
Model-code position XI J decodes to 316 stainless steel 1/4 in NPT fittings
Controls
Decoded valve type
Model-code position XII U decodes to a medium-flow Cartridge III valve in 316 stainless steel
Decoded valve/controller location
Model-code position XIII 5 decodes to outlet location with back inlet and back outlet connection orientation
Options
Decoded alarms
Model-code position XIV A decodes to no alarm option
Decoded additional option
Model-code position XV R decodes to stainless steel tag
Decoded certification option
Model-code position XVI A decodes to no additional certification option
Installation
Mounting orientation
Variable-area glass tube meters are read in vertical installation with bottom-to-top flow as described in the installation manual
Configuration
Configured-unit rule
Tube, float, scale, connection, valve, seal, option, certification, and calibrated fluid context are model-code and unit-label specific