1350EN2CCJV1A is a configured Brooks Instrument Sho-Rate 1350E glass tube variable-area flowmeter identifier observed in Sonisys auction records. exact-match evidence is listing-level, while Brooks 1350E/1355E documentation supports the family identity, glass-tube variable-area construction, scale, pressure/temperature, valve, flow-controller, installation, and service context. The exact tube/float code, scale, flow range, fluid, valve, materials, and connection details must be verified from the physical meter
Configurations vary. Verify the exact unit before choosing a replacement.
Stored auction records identify this exact configured part as BROOKS INSTRUMENT 1350EN2CCJV1A FLOW METER and BROOKS 1350EN2CCJV1A FLOW METER UNMP
Flow
Measuring principle
Variable-area rotameter with tapered glass metering tube and metering float
Configured flow range
No exact flow range was extractable from the stored titles for 1350EN2CCJV1A; verify from the scale and tube/float code
Family capacities
1350E/1355E capacities are tube, float, fluid, scale, and model dependent; use the local Brooks manual tables only after matching the physical tube/float code
Scale
1350E scale context
Brooks 1350E/1355E manual lists the 1350 Series scale length as 65 mm nominal, with R-65 mm or R-100 linear reference scale options and calibration tables
Valve/Control
Valve and controller options
Brooks 1350E/1355E documentation describes optional standard needle valves, NRS integral control valves, and FC8800 or FC8900 flow-controller options
Pressure/Temperature
Manual pressure/temperature context
Brooks 1350E/1355E manual lists 170 psig at 33 F to 250 F / 1 C to 121 C in its pressure-temperature context
Installation
Connection context
Brooks 1350E/1355E manual describes normally horizontal female NPT process connections and supported piping to avoid strain on the meter
Maintenance
Tube and float service
Brooks 1350E/1355E manual describes quick removal or installation of tube and float while the meter remains in process piping, with periodic inspection and cleaning
Applications
Application domain
Low-flow gas and liquid indication or control depending on model, tube/float, valve, scale, and controller configuration
Configuration
Configured-unit rule
Verify tube/float code, scale, flow range, process fluid, valve or controller option, end-block material, seals, connection type, and pressure/temperature rating from the physical meter
Documents
Hosted documentation
Sonisys hosts local PDF copies of the Brooks Sho-Rate 1350E/1355E datasheet and installation/operation manual