Brooks Instrument Sho-Rate 1350E Variable Area Flowmeter with 8800 Controller Context
About this part
1350ELA1CJV1A8800D3J2B1CA is a configured Brooks Instrument Sho-Rate 50 / Model 1350E glass tube variable-area flowmeter identifier with an 8800 controller-style suffix context. Official Brooks 1350E/1355E documentation provides family-level flowmeter construction, accuracy, pressure/temperature, scale, connection, valve, controller, and installation context, and official Brooks FC 8800/8900 documentation explains the associated flow-controller family. Stored Sonisys auction records identify this exact code as a Brooks variable-area flow meter with observed 0-100 scale and 1/4 inch NPT wording. Exact tube, float, calibrated fluid, direct-reading scale, valve or controller option, end-block material, seal material, connection, pressure certification, and flow range must be verified from the physical unit label and scale markings
Configurations vary. Verify the exact unit before choosing a replacement.
Application classIndustrial automation and process equipment
CategoryFlow Control
Specifications
Identification
Device type
Glass tube variable-area flowmeter / rotameter
Series family
Brooks Sho-Rate 1350E / 1355E family
1350E family name
Sho-Rate 50
Configured model code
1350ELA1CJV1A8800D3J2B1CA
Function
Measuring principle
Variable-area flow indication using a tapered glass metering tube and metering float
Scale
1350 series scale length
65 mm nominal
Scale options
Standard R-65 mm or R-100 linear reference scale with air or water calibration table, depending on configuration
Performance
1350 Series accuracy
Brooks 1350E/1355E data sheet lists 1350 Series standard accuracy as +/-10% full scale
1355 Series accuracy
Brooks 1350E/1355E data sheet lists 1355 Series standard accuracy as +/-5% full scale
Repeatability
Brooks 1350E/1355E data sheet lists repeatability as 0.5% full scale
Pressure and temperature
Standard pressure and temperature rating
Brooks 1350E/1355E documentation lists 200 psig from 33 F to 250 F / 1 C to 121 C
CRN pressure and temperature context
Brooks 1350E/1355E documentation lists 170 psig from 33 F to 250 F / 1 C to 121 C when supplied under CRN certification
Construction
Metering tube material
Borosilicate glass
Float material options
Glass, 316 stainless steel, sapphire, Carboloy, and tantalum
End fitting material options
Chrome plated brass, black anodized aluminum, and 316 stainless steel
Connections
Standard 1350E family connection
Horizontal female 1/8 inch NPT threaded adapters with locknuts for front panel mounting
Optional connection context
Brooks 1350E/1355E documentation lists optional compression, 1/4 inch female NPT, hose, VCR, and Rc connection configurations
Controls
Integral control options
Standard integral flow control valve, NRS integral flow control valve, and 8800/8900 integral flow controller configurations are supported by the family documentation
8800 controller context
Brooks FC documentation identifies Series FC 8800 controllers for maintaining liquid and gas flows with variable upstream pressure; the full Sonisys code includes an 8800-style suffix that should be verified on the unit label
Installation
Orientation
Install within 6 degrees of true vertical with inlet connection at the bottom end fitting
Configuration
Configured-unit rule
Tube, float, direct-reading scale, valve or controller option, end-block material, seal material, process connection, calibrated fluid/range, pressure certification, and flow-controller code details vary by configured unit and must be verified from the physical unit
Observed variants
Stored auction context
Stored Sonisys auction evidence identifies this exact code as a Brooks variable-area flow meter and includes observed 0-100 scale and 1/4 inch NPT wording
Applications
Application domain
Low-flow gas and liquid indication, purge flow service, panel-mounted rotameter applications, and configured flow-control assemblies