1350EBA7AGV1A is a configured Brooks Instrument Sho-Rate 1350E glass tube variable-area flowmeter identifier. Stored Sonisys listings identify standard flow-meter units plus configured variants using 8800D2J1A1CA and FCA8800A3B1A0A0A1 context; one stored listing reports a.4-2.0 SCFH range. Brooks 1350E/1355E documentation supports the Sho-Rate 50/150 family identity, glass-tube variable-area construction, scale, pressure/temperature, valve, and flow-controller options, while exact tube/float/scale, fluid, range, valve, and controller configuration must be verified from the physical meter
Configurations vary. Verify the exact unit before choosing a replacement.
Variable-area rotameter with tapered glass metering tube and metering float
Observed configured range
One stored listing reports.4-2.0 SCFH; treat this as an observed auction variant unless confirmed on the physical scale
Family capacities
1350E/1355E capacities are tube, float, fluid, scale, and model dependent; use the local Brooks manual tables only after matching the physical tube/float code
Scale
1350E scale context
Brooks 1350E/1355E manual lists the 1350 Series scale length as 65 mm nominal, with R-65 mm or R-100 linear reference scale options and calibration tables
Valve/Control
Valve and controller options
Brooks 1350E/1355E documentation describes optional standard needle valves, NRS integral control valves, and FC8800 or FC8900 flow-controller options
Observed controller context
Stored titles include 8800D2J1A1CA and FCA8800A3B1A0A0A1 context; verify whether these identify installed flow-controller or accessory configuration on the physical unit
Pressure/Temperature
Manual pressure/temperature context
Brooks 1350E/1355E manual lists 170 psig at 33 F to 250 F / 1 C to 121 C in its pressure-temperature context
Installation
Connection context
Brooks 1350E/1355E manual describes normally horizontal female NPT process connections and supported piping to avoid strain on the meter
Maintenance
Tube and float service
Brooks 1350E/1355E manual describes quick removal or installation of tube and float while the meter remains in process piping, with periodic inspection and cleaning
Applications
Application domain
Low-flow gas and liquid indication or control depending on model, tube/float, valve, scale, and controller configuration
Configuration
Configured-unit rule
Verify tube/float code, scale, flow range, process fluid, valve or controller option, end-block material, seals, connection type, and pressure/temperature rating from the physical meter
Documents
Hosted documentation
Sonisys hosts local PDF copies of the Brooks Sho-Rate 1350E/1355E datasheet and installation/operation manual