Flow Control
11117DZ01R
Brooks Instrument Glass-Tube Variable-Area Flowmeter
About this part
The physical manufacturer label identifies model 11117DZ01R as a Brooks Instrument product. The unit is an industrial glass-tube variable-area flowmeter consistent with Brooks Full-View construction. Brooks documentation for the 1110/1140 Full-View family provides applicable operating, construction, and safety guidance, but its published ordering tables do not decode 11117DZ01R end to end. The unit's flow range, scale calibration, pressure rating, process connections, wetted materials, and options therefore remain configuration-specific
Configurations vary. Verify the exact unit before choosing a replacement.
Key Facts
Specifications
| Manufacturer | Brooks Instrument; the physical label names Brooks Instrument Division, Emerson Electric Co |
| Model | 11117DZ01R, confirmed by the physical manufacturer label |
| Instrument type | Industrial glass-tube variable-area flowmeter for visual flow indication |
| Measurable media | Brooks Full-View 1110/1140 family: liquids and gases; the exact calibrated fluid for 11117DZ01R is not established |
| Metering tube | Borosilicate glass |
| Seal construction | Externally adjustable packing-gland construction |
| Flow accuracy | Standard ±2% of full scale; optional ±1% of full scale for 127, 150, and 250 mm tubes. The accuracy option fitted to 11117DZ01R is not established |
| Repeatability | 0.5% of full scale |
| Ambient temperature | 33 to 125 °F (1 to 52 °C) |
| Operating-fluid temperature | 33 to 250 °F (1 to 121 °C) with metallic end fittings; reduced limits apply to nonmetallic fittings |
| Connection formats | Female NPT or 150 lb raised-face flange, depending on configuration; inlet and outlet may be horizontal or vertical |
| Maximum non-shock pressure | Configuration-dependent. Published metallic-end family ratings span 75 to 500 psig according to meter size; this range is not the exact rating of 11117DZ01R |
| Flow range and scale | Not established; the archived scale/data-tag values are not legible enough for a reliable transcription |
| Connection size and orientation | Not established; the complete identifier cannot be decoded with the published standard ordering tables |
| Wetted materials and seals | Not established for the exact unit |
| Pressure and temperature limits | Use the unit data tag or original calibration documentation; family maxima must not be applied as exact configured limits |
Published model-code applicability
The exact label identifier must be retained intact rather than force-decoded from a later standard ordering table.
| Evidence | Published information | Exact-unit judgment |
|---|---|---|
| Physical model label | 11117DZ01R | Exact model identifier confirmed |
| Brooks 2011 and revision 0414 ordering tables | Standard codes are assembled from base model, connection orientation, meter size, tube, float, scale, materials, connection type, and accessories | 11117DZ01R does not match the published positional options end to end |
| Configuration result | The standard tables can describe documented 1110/1140 configurations | No meter size, tube, float, scale, material, connection, or accessory code is assigned to 11117DZ01R from those tables |
Document revisions and conflicts
The available Brooks documents describe the family but contain revision boundaries that prevent exact suffix decoding.
- The manufacturer-hosted data sheet is DS-VA-1110-1140-eng, revision 0414.
- The installation and operation manual is X-VA-1110-1140-eng, part number 541B040AAG, dated September 2012.
- The revision 0414 data sheet lists scale lengths as 127, 200, and 250 mm in one specification line, while its accuracy statement and capacity tables use 127, 150, and 250 mm. The September 2012 manual and April 2011 data sheet also specify 127, 150, and 250 mm; 150 mm is therefore the supported family value.
- The April 2011 data sheet and September 2012 manual include meter size 7. The revision 0414 ordering table omits size 7. This revision difference is not used to infer the size of 11117DZ01R.
Glass-tube safety guidance
Brooks treats the pressurized glass tube as an explosion hazard if the meter is misapplied or serviced incorrectly.
- Keep the protective sleeve over the glass tube where required by meter size and fasten the meter windows securely.
- Do not operate above the pressure or temperature limits marked for the configured meter.
- Avoid pressure and flow surges; introduce flow slowly.
- Depressurize the meter before service or repair.
Replacement relationship
Brooks identifies the GT1600 Series as configurable to retrofit Full-View 1100 Series models 1110, 1114, 1140, and 1144. This is a family replacement relationship, not an exact drop-in approval for 11117DZ01R. Replacement selection requires confirmation of the original flow calibration, tube and float, process connections, materials, pressure rating, and mounting dimensions.
Documentation Downloads
Local PDF copiesPart Photos
3 imagesHistorical archive images for identification, labels, connectors, and condition reference, not current inventory.
Historical Listings & Prices
Historical listing data, not a current offerThe typical recorded price range is $179.10 to $179.10. Based on 1 archived listing record; not a current offer, appraisal, or confirmed sale price.
View archived listing titles
- NEW BROOKS INSTRUMENT 11117DZ01R FLOW METER