Brooks Instrument Full-View Variable Area Flowmeter
About this part
1110DL24C4DAA is a configured Brooks Instrument Model 1110 Full-View glass tube variable-area flowmeter identifier. Official Brooks 1110/1140 documentation identifies Model 1110 as the NPT-connection Full-View flowmeter family. Stored Sonisys auction evidence and distributor references for this exact identifier describe a 0-9.94 GPM, 3/4 inch NPT variable-area flowmeter, but the physical unit label and installed scale remain authoritative for tube, float, scale, valve, material, pressure rating, and service-fluid details
Unit-specific configuration
Observed configuration
Historical listing records identify this part as 0-9.94 GPM. Exact gas, range, fittings, valve configuration, and communication interface must be verified from the physical unit label.
Configurations vary. Verify the exact unit before choosing a replacement.
Application classLife sciences and laboratory automation
CategoryFlow Control
Specifications
Identification
Device type
Full-View glass tube variable-area flowmeter
Series family
Brooks 1110/1140 Series Full-View glass tube flowmeters
Model family
Brooks Model 1110 Full-View flowmeter with NPT connections
Configured part identifier
1110DL24C4DAA
Flow
Measuring principle
Variable-area glass-tube flow measurement for gases or liquids depending on tube, float, scale, and materials
Mechanical
Connection family
Official 1110/1140 documentation identifies NPT female connections for Model 1110; fitting size and orientation vary by configured meter size
Construction context
Brooks 1110/1140 documentation describes Full-View glass tube meters with packing gland seal construction, rugged dowel-pin side-plate construction, and borosilicate glass metering tubes
Performance
Family accuracy context
Official 1110/1140 documentation lists standard flow accuracy as +/-2% full scale and optional flow accuracy as +/-1% full scale for 127 mm, 150 mm, and 250 mm tubes
Installation
Mounting orientation
Brooks 1110/1140 installation guidance describes mounting the Full-View flowmeter within 6 degrees of true vertical, with inlet at the bottom and outlet at the top
Configuration
Configured-unit rule
Tube, float, valve, scale, material, fitting, pressure rating, temperature rating, and service fluid vary by configured model code and unit label
Observed variants
Stored auction flow/connection context
Stored exact-code title evidence includes 0-9.94 GPM and 3/4 inch NPT wording
Applications
Application domain
Industrial flow indication, purge flow, gas/liquid process service, laboratory flow measurement, and equipment support