Brooks Instrument 1110DG41CSAAR is a legacy Full-View Model 1110 variable-area flowmeter configured with 1/4-inch female NPT horizontal inlet and outlet connections, a size-6 R-6-25-A borosilicate metering tube, a spherical 316 stainless-steel float, steel fittings with PTFE packing and O-ring, and a special ±1% full-scale water calibration. The ordering code also specifies NIST traceability. Brooks publishes 485 cc/min water as the reference maximum capacity for the code-matched tube and float; the serialized meter scale remains authoritative for its calibrated range
Configurations vary. Verify the exact unit before choosing a replacement.
ManufacturerBrooks Instrument Full-View 1110 Series
Part number1110DG41CSAAR
Product familyConfiguration-specific
Device typeFlowmeter
Configuration statusConfiguration varies
Application classIndustrial automation and process equipment
CategoryFlow Control
Specifications
Identification
Product series
Brooks Full-View 1110 Series
Measurement principle
Direct-reading variable-area flow measurement
Configuration
Base model
1110; threaded Full-View flowmeter
Meter size
Size 6
Inlet and outlet orientation
Horizontal inlet and horizontal outlet
Connections
Process connections
1/4-inch female NPT
Metering assembly
Metering tube
R-6-25-A borosilicate glass tube
Nominal scale length
250 mm
Float
Spherical, 316 stainless steel
Calibration
Scale and calibration
Special water calibration, ±1% of full scale
Traceability option
NIST traceable
Materials
End fittings
Steel
Packing and O-ring
PTFE
Performance
Published water capacity
485 cc/min maximum for the R-6-25-A tube with 316 stainless-steel float
Published air capacity
16.2 standard L/min maximum at 14.7 psia and 70°F (21.1°C) for the same tube and float
Repeatability
0.5% of full scale
Pressure and temperature
Maximum non-shock operating pressure
450 psig at 70°F, 150°F, or 250°F for a size-6 meter with metallic end fittings
Ambient temperature range
33 to 125°F (1 to 52°C)
Process-fluid temperature range
33 to 250°F (1 to 121°C) with metallic end fittings
Model-code decoding
The complete identifier is supported by the April 2011 Brooks ordering matrix, which retains legacy options omitted from later revisions.
Segment
Ordering category
Decoded configuration
111
Base model
Threaded industrial glass-tube flowmeter
0D
Connection orientation
Horizontal inlet; horizontal outlet
G
Meter size
Size 6
4
Tube designator
R-6-25-A
1
Float designator
Spherical float
C
Float material
316 stainless steel
S
Scale
Special calibration with ±1% full-scale water scale
A
Materials of construction
Steel fittings; PTFE packing; PTFE O-ring
A
Connection type
NPT
R
Accessory
NIST traceable
Published capacity reference
These values are the Brooks capacity-table ratings for the decoded R-6-25-A tube and 316 stainless-steel spherical float. The physical scale governs the serialized meter's calibrated full-scale value.
Reference fluid
Maximum flow
Published conditions
Water
485 cc/min
Brooks 250 mm spherical-float capacity table
Air
16.2 standard L/min
14.7 psia and 70°F (21.1°C)
Installation and operating notes
Install the flowmeter within 6 degrees of true vertical, with flow entering at the bottom and leaving at the top.
Introduce flow slowly and avoid pressure or flow surges.
Brooks recommends bypass piping so the meter can be isolated for servicing and cleaning.
Do not exceed the applicable pressure or temperature limits or service the meter while it is pressurized.
Legacy status and replacement
Brooks classifies the Full-View 1100 Series as a legacy product.
Current replacement familyBrooks GT1600 Series
Compatibility scopeThe GT1600 can be configured to retrofit Full-View models 1110, 1114, 1140, and 1144.
Selection requirementA replacement must be configured for the original connection arrangement, capacity, wetted materials, and calibration; family-level retrofit capability does not establish a direct one-for-one replacement for 1110DG41CSAAR.