Load Ports
013096-809-20
Brooks Automation FixLoad 6M Load Port Module
About this part
Brooks Automation 013096-809-20 is a configured assembly in the FixLoad 6M family of 300 mm FOUP load ports. FixLoad 6M provides the carrier-to-equipment interface for automated semiconductor wafer handling. Mapping, E84 automation hardware, controller interfaces, and other options are configuration-dependent and must be confirmed from the unit nameplate or build record before substitution
Configurations vary. Verify the exact unit before choosing a replacement.
Key Facts
Specifications
| Manufacturer | Brooks Automation |
| Part number | 013096-809-20 |
| Product family | FixLoad 6M |
| Equipment class | 300 mm FOUP load port module |
| Optional wafer mapping | FixLoad 6M configurations with load-port mapping can use a through-beam mapper to identify present, missing, cross-slotted, and double-slotted wafers |
| Controller link | Brooks MagnaTran LEAP software documents a FIXLOAD link type for communication with a FixLoad 6M load port module through a DNETSGW4 connection |
Configuration boundary
The complete 013096-809-20 identifier denotes a configured assembly. Other 013096-series suffixes occur on distinct FixLoad 6M builds and are not interchangeable aliases. Confirm the mapper, E84 hardware, communications modules, connector arrangement, mounting interface, and carrier interface from the unit label and Brooks build documentation before replacement.
Documented family options
Controller integration reference
These values describe the configurable MagnaTran LEAP controller link for the FixLoad 6M family; they do not establish the installed interface on 013096-809-20.
| Interface element | Documented value | Scope |
|---|---|---|
| Link type | FIXLOAD | Robot link to a FixLoad 6M load port module |
| Gateway type | DNETSGW4 | FixLoad 6M connection associated with SI30 through SI39 |
| Gateway capacity | Four serial ports | DeviceNet serial-gateway description |
| Selectable baud rate | 9600 or 19200 baud | Controller-link configuration |
| Selectable serial framing | 7 or 8 data bits; none, even, or odd parity; 1 or 2 stop bits | Controller-link configuration |
| Activation requirement | Controller reboot after changing link settings | MagnaTran LEAP controller behavior |
Documentation Downloads
Local PDF copiesPart Photos
5 imagesHistorical archive images for identification, labels, connectors, and condition reference, not current inventory.
Historical Listings & Prices
Historical listing data, not a current offerThe typical recorded price range is $12,000.00 to $12,000.00. Based on 1 archived listing record; not a current offer, appraisal, or confirmed sale price.
View archived listing titles
- Brooks Automation Fixload 6M 013096-809-20 Load Port